Last edited by Zulkizahn
Monday, July 13, 2020 | History

2 edition of Spectrographic analysis of platinum, palladium and gold in assay beads. found in the catalog.

Spectrographic analysis of platinum, palladium and gold in assay beads.

John Seath

Spectrographic analysis of platinum, palladium and gold in assay beads.

by John Seath

  • 52 Want to read
  • 8 Currently reading

Published .
Written in English


Edition Notes

Thesis (M.A.) -- University of Toronto, 1938.

The Physical Object
Pagination1 v.
ID Numbers
Open LibraryOL16388354M

Fire-Assay Emission Spectrographic Method for Platinum, Palladium, Rhodium, and Gold. Appl. Spectr., v. 24, No. 2, , pp. 12 APPENDIX A.— STATE LIAISON OFFICES Local Information The U.S. Department of the Interior has established, through its Bureau of Mines, State Liaison Officers to represent each of the States and terri- tories. or gold beads A successful application of spark-ablation ICP-MS for the direct detection of platinum, palladium, rhodium and iridium in the gold and silver beads was demonstrated The application of other iron-nickel-copper,29 copper,30,31 tin,32,33 and NiS34 fire assay collectors for precious metals has been proposed.

Ten-karat gold is marked 10k, 16, , or 10KP; karat gold is marked , , or 14KP; karat gold is marked or 18KP; karat gold is marked or ; and pure gold, 24 karat, is marked Marked platinum will say Plat, Plat , Pt, or Pt. Modern palladium . Absolutely, the best way to assay for gold, silver, platinum & palladium. Jones Street. Bodfish, CA Ph: (Please call between 9 A.M. & 9 P.M. California Time) E-Mail: [email protected] Butler Labs Oxyacetylene Torch Assaying. The .

(). Determination of Ultra-Trace Platinum, Palladium, Ruthenium, Rhodium, and Iridium in Rocks and Minerals by Inductively Coupled–Plasma Mass Spectrometry Following Nickel Sulfide Fire Assay Preconcentration and Open Mixed Acid Digestion. Analytical Letters: Vol. 52, No. 11, pp. A method validation study for Iridium, Palladium, Platinum, Rhodium and Ruthenium was performed on a sample of polyethylene glycol in accor-dance with USP. The analysis utilized an ICP-MS and evaluated Iridium, Palladium, Platinum, Rhodium and Ruthenium based on 6 validation characteristics: precision, accuracy, linearity, spec -.


Share this book
You might also like
Analysis of cracks perpendicular to bimaterial interfaces using a novel finite element

Analysis of cracks perpendicular to bimaterial interfaces using a novel finite element

Barriers and bridges.

Barriers and bridges.

Black gold

Black gold

Environmental planning

Environmental planning

electrical strain gage for the tensile testing of paper

electrical strain gage for the tensile testing of paper

farm journal directory of Ashland County, Ohio

farm journal directory of Ashland County, Ohio

J. Franklin Little

J. Franklin Little

The Writings of George Washington from the Original Manuscript Sources 1975-1799 Volume 33 July 1, 1793-October 9, 1794

The Writings of George Washington from the Original Manuscript Sources 1975-1799 Volume 33 July 1, 1793-October 9, 1794

working life, cruel beyond belief

working life, cruel beyond belief

IEEE trial-use standard for artificial intelligence exchange and service tie to all test environments (AI-ESTATE)

IEEE trial-use standard for artificial intelligence exchange and service tie to all test environments (AI-ESTATE)

The Websters

The Websters

Cork Street, next to the hatters

Cork Street, next to the hatters

Dark star

Dark star

Spectrographic analysis of platinum, palladium and gold in assay beads by John Seath Download PDF EPUB FB2

Spectrographic Examination of Assay Beads for Platinum, Palladium, and Gold Article in Industrial palladium and gold in assay beads. book Engineering Chemistry Analytical Edition 10(9) May with 4 Reads How we measure 'reads'. Platinum, palladium, and rhodium are determined by direct spectrographic analysis of a 4 mg gold bead obtained by fire assay fusion and cupellation.

The weighed bead is placed into a graphite electrode containing 2 mg of (NH4)2 OsCl5 which stabilizes the platinum volatilization and is burned in a 15 A dc arc in an argon–oxygen atmosphere.

Direct Spectrographic Analysis for Platinum, Palladium, and Rhodium in Gold Beads from Fire AssayCited by: 9.

"IntroductionIN THE COURSE of. a spectrographic investigation of the platinum t of various minerals in sulphide ores, the use of • fire-assay beads dissolved in gold-amalgam (1) was found suitable for the quantitative determination of palladium and platinum. VOL. 9 () ANALYTICA CHIMICA ACTA 49 THE DETERMINATION OF PLATINUM, PALLADIUM AND GOLD IN SILVER ASSAY BEADS by R.

BAREFOOT AND x'. BEAMISH Øepartmeitt of Chrrtiistry, University o/ Toronto, Toronto, Ontario (Canada) INTRODUCTION This investigation was undertaken in order to find a new procedure for the rapid analysis of silver beads which contain the soluble platinum Cited by: 3.

A method is described for the determination of gold, platinum, palladium, rhodium and iridium at microgram levels in geological and other materials by a combination of fire-assay preconcentration and emission spectrography. The noble metals are collected into 4-mg silver or platinum prills by a normal fire-assay technique.

Ind. Eng. Chem. Anal. All Publications/Website. OR SEARCH CITATIONS. Spectrographic Examination of Assay Beads for Platinum, Palladium, and Gold Analysis of Platinum Metals--Silver Assay Bead A volumetric method has been devised for. The Assay of the Platinum Metals.

Platinum prepares for new rise – Analysis – GMT () Platinum price kept its positive stability above the moving average 55 to reinforce the domination of the bullish bias, settling near as appears on the chart, also, stochastic attempt to crawl.

A method has been developed for the determination of microgram levels of Pt, Pd, Rh, and Au. A mg Ag bead containing the precious metals, as extracted by fire assaying, is arced at 8 A dc in graphite electrodes in the presence of 10 mg of either Rh or Pt metal powder.

The matrix elements, Ag and Pt, or Rh, serve as internal standards, and intensity ratios Pt/Rh or Rh/Pt, Pd/Rh, and Au/Ag. analysis. The combination method of analysis of Haffty and Riley () was used to obtain the v a 1 u e s of the platinum-group metals reported in this paper. In this method, fire-assay techniques are used to collect the Pt-Pd-Rh of the sample into a gold bead; this bead is.

Purchase Analysis of Noble Metals - 1st Edition. Print Book & E-Book. ISBNA method is presented for the determination of microgram levels of Ir, Ru, and Os in ores, concentrates, and heavy sands.

Radiotracers are used to monitor the recovery of these three metals in a mg Pt bead during the normal fire assaying procedure. The Pt bead is arced at 20 A dc in a graphite electrode, and Pt serves as an internal standard. A procedure is given for the atomic absorption determination of platinum, palladium and gold in silver beads.

Interferences by coexisting ions usually found in the parting solution could be eliminated by addition of 1% of lanthanum. The lowest working ranges in which it is possible to obtain results comparable in accuracy to those from a good spectrophotometric determination are estimated for. Gold Analysis.

Silver Analysis. Platinum group Analysis. Palladium, platinum, and rhodium by fire-assay preconcentration and emis­ atomic absorption spectroscopy, emission-spectrographic analysis, or neutron-activation analysis. An exception is the silver method which.

This test method covers the spectrographic analysis of ores, minerals, and rocks for silver, palladium, platinum, gold and rhodium. The concentrations of precious metals which can be determined in the material being analyzed depend on the amount of sample assayed (Note 1).

Concentration ranges for the lead fire assay beads are as follows. A combined fire assay-wet chemical procedure for the accurate and rapid determination of platinum, palladium, gold and silver is described. The sample is fused with lead flux and the lead button is parted with perchloric acid after heating at – °C.

After dilution of the parting solution with water, a formic a. This is the third video in a series on sampling and analysis of precious metals. Instrumental Methods for Gold, Silver, Platinum, Palladium and other PGMs - Gold Fire Assay.

Like platinum, palladium is another high quality white colored precious metal used for jewelry. If someone brings in some metal to sell and calls it palladium, you can test it in much the same way you would test gold to be sure that it is what they claim it is before buying it.

Tools Needed: A testing stone; And 18 or 22 karat gold testing acid. If platinum, palladium, or rhodium are present, they dissolve in the molten lead and are collected in the gold-silver bead after cupellation.

Their concentration in the gold after parting can be determined by arc spectrography. If iridium is present, it forms a black deposit that clings to the doré bead.allofthethreemetals,palladium,rhodium,seduponthe complete precipitationof thehydrated dioxidesof palladium,rhodium, and iridium in a boilingsolution .Fire-assay emission spectrographic method for platinum, palladium, rhodium, and gold.

pd, rh, and au. A mg ag bead containing the precious metals, as extracted by fire assaying, is arced at 10 a DC in graphic electrodes in the presence of 10 mg of either rh or pt metal powder. +/ percent for pd, and +/- 19 percent for au.

Limits.